Walk the record of a company that began galvanizing steel drums in Emeryville, California, in 1925 and has built water heaters continuously since 1931. The exhibits run founding to centennial. The anatomy table opens a storage tank down to its sacrificial anode. The decoder teaches the three numbers on every spec label. Tank, tankless, and ProTerra heat-pump families are stocked at Super Arbor, and the desk notes explain how to choose among them.
Wing I
The record
Eight exhibits, one century.
Exhibit 01 — 1925
Galvanizing in Emeryville
Brothers Richard and Donald Rheem established the company in Emeryville, California, galvanizing steel drums and other metal products for the petroleum trade — a third brother, William, is named among the founders in Rheem's own centennial telling. The family name has been on the product ever since — first on drums, soon on tanks.

Exhibit 02 — 1931
Into water heating
Six years in, Rheem acquired the John Wood Manufacturing line and began producing automatic gas storage water heaters. Water heating became the company's defining trade, and its own timeline notes the focus has continued to the present day.

Exhibit 03 — 1947
Heating and cooling the house
Rheem purchased the Fraser line of gas furnaces and winter air conditioners, anticipating a market for central heating and cooling. The Rheemaire central air system followed in 1956, and HVAC has run alongside water heating in the catalog ever since.
Exhibit 04 — 1960
Ruud joins the house
Rheem purchased Ruud Manufacturing's water heater business, gaining a broader commercial line, a second distribution network, and — in the company's words — a second respected brand name. Ruud remains a sister nameplate in the Rheem family today.
Exhibit 05 — 1988
A global owner, a southern address
Rheem became a wholly owned subsidiary of Paloma Industries of Japan, one of the world's leading producers of gas appliances, as the company's centennial timeline records it. Operations continued under the Rheem name, and headquarters moved to Atlanta, Georgia, in 2007.
Exhibit 06 — 2009
The hybrid bet
Per Rheem, the company was first to launch a hybrid heat pump water heater, rated at more than twice the efficiency of standard electric models. Over the following decade, heat-pump water heating moved from novelty to a mainstream residential category.
Exhibit 07 — 2020
ProTerra
Rheem introduced ProTerra, the hybrid electric heat pump water heater it describes as the industry's most efficient, with models rated up to 4.07 UEF. A condensing tankless line had joined the catalog in 2010, rounding out three ways to heat water.
Exhibit 08 — 2025
One hundred years
Rheem marked a century in business — from galvanized drums in Emeryville to water heating and air systems sold worldwide. The company's centennial telling counts more than 500 patents and an unbroken line of water heaters built since 1931.
Interactive exhibit
One tank, opened apart
A storage water heater, separated into the parts the spec label never mentions. Open each numbered plate.

- 01
Anode rod — the sacrificial part
A magnesium or aluminum rod threaded into the tank corrodes on purpose: its metal gives up electrons more readily than steel, so water attacks the rod instead of the tank wall. Rheem's parts guidance calls anode rods the most important line of defense in extending tank life and preventing leaks — and notes that a depleted rod protects nothing. Inspection is on every use-and-care schedule.
- 02
Dip tube
Cold water enters at the top of the tank but must be heated from the bottom. The dip tube — a plastic pipe running from the cold inlet down the tank interior — delivers incoming water to the base, where the burner or lower element works, while the hottest water stays stratified at the top for the outlet. Rheem lists open, helix, and closed outlet types, each distributing water differently.
- 03
Burner or elements
Gas tanks heat from a burner beneath the tank, rated by input in BTU per hour — 40,000 BTU/h is typical on residential 50-gallon models. Electric tanks use two immersed resistance elements, commonly 4,500 watts, wired to fire one at a time in most residential designs. That recovery rate — not the gallon count — is what separates two same-size tanks on delivered hot water.
- 04
T&P relief valve
The temperature and pressure relief valve is the tank's safety device: per Rheem's parts documentation, it opens to let water escape in the unlikely event that tank temperature or pressure becomes excessive. Local code governs its discharge piping, and it is never to be capped or plugged. A dripping T&P valve is a symptom to diagnose, not a leak to silence.
- 05
Insulation jacket
Between the steel tank and the outer shell sits foam insulation that limits standby loss — the heat a full tank sheds while waiting for a draw. DOE's efficiency test accounts for standby losses over a 24-hour period, which is why UEF rewards a well-insulated tank. Rheem's spec pages describe isolated tank designs that reduce conductive heat loss.
Stylized CGI rendering — an illustration of tank construction, not a Rheem drawing.
The families, explained
Tank. Tankless. Hybrid.
Three ways to heat water — standing inventory, on-demand flow, and the heat pump that moves heat instead of making it.
40–50 GAL
Storage tank — gas and electric
The standing-inventory model: a Rheemglas-lined steel tank keeps hot water ready around the clock, gas burner below or electric elements within. Rheem's retail tiers carry Performance and Performance Platinum names; its contractor catalog runs Professional Classic, Classic Plus, and Prestige. Common residential sizes are 40 and 50 gallons, with short, tall, and larger formats around them; warranties run roughly six to twelve years by model. Read the first-hour rating before the gallon stamp.
FitsThe like-for-like swap when fuel, venting, and floor space already exist.
11.2 GPM
Tankless — on-demand
No stored gallons: water heats as it flows, so output is rated in gallons per minute at a given temperature rise rather than capacity. Rheem's condensing IKONIC gas line runs 8.4–11.2 GPM at 0.96 UEF; non-condensing RTG models rate 0.82 UEF; compact RTEX electric units run from single-fixture point-of-use sizes up to roughly 4-GPM models. Hot water is continuous within flow limits — but sizing, gas supply, and venting are a different exercise from tanks, and a specialist's call.
FitsTight spaces and households that outrun a tank's first hour — sized in GPM and temperature rise.
4.07 UEF
ProTerra — hybrid heat pump
A heat pump mounted on a storage tank: it moves heat from the surrounding air into the water instead of generating it — a method New York's NYSERDA credits with around three times the efficiency of standard electric models. Rheem rates ProTerra models up to 4.07 UEF, with resistance elements as hybrid backup for heavy draws; per Rheem, that is up to 75 percent less energy than a standard electric tank. Supply-circuit, clearance, and air-space requirements vary by model.
FitsAll-electric homes chasing operating cost; confirm circuit, height, and airflow first.
Size by first-hour rating, not tank gallons. DOE sizing guidance matches a tank's FHR — the hot water it can deliver in a busy hour — to your household's peak-hour demand; a bigger tank with slow recovery can deliver less. Fuel type, venting, gas line, circuit capacity, and drainage are local-code and licensed-installer territory — confirm before purchase.
Read the label
The spec label, decoded
Every storage water heater carries the same three numbers — gallons, first-hour rating, and UEF. Only one of them sizes your house.
50 GAL
Storage capacity — what it holds
Rated capacity is the water the tank physically contains — in Rheem's EnergyGuide explainer, "the actual amount of water the unit contains." It is the least useful number on the label for sizing: two 50-gallon units with different burners or elements deliver very different amounts of hot water in an hour. Gallons describe storage, not delivery, and buying by gallons alone is the category's classic mistake.
FHR 62
First-hour rating — what it delivers
DOE defines first-hour rating as the maximum gallons of hot water a fully heated tank can supply within one hour — stored volume plus recovery rate combined. It prints on the yellow EnergyGuide label required on storage water heaters. DOE sizing guidance says to estimate the busiest hour's hot-water demand and match FHR to it. This, not the gallon stamp, is the number that sizes a household.
UEF 0.93
Efficiency and recovery input
Uniform Energy Factor, DOE's 2017 metric, is the share of consumed energy that ends up as hot water over a 24-hour test; compare it only within the same usage bin, which is assigned by FHR. The trailing figure is recovery input: electric tanks list element wattage, commonly 4,500 W, while gas tanks list burner input in BTU per hour — typically 40,000 on 50-gallon residential models.
Hybrids read differently: a heat pump moves heat from the air rather than generating it, so ProTerra-class units rate up to 4.07 UEF — an efficiency multiple, not extra stored gallons. Specimen figures are illustrative of a common 50-gallon electric label; individual models vary.
The desk's read
How the desk checks a water-heater order
The order logic nobody writes down — voiced as our desk's read, not the brand's claim.
Which line to buy
The desk's read: the maker is identical; the tier names track the sales channel. Performance-series tanks are the retail route, while Professional Classic and Prestige models list on Rheem's own catalog and move through plumbing distributors. If a licensed plumber is installing anyway, price both routes before defaulting to either. Then compare the honest way — first-hour rating, UEF, and warranty term, model against model, not name against name.
The sizing math
The desk's read: count your worst hour, not your bathrooms. Add back-to-back showers, the dishwasher, and a laundry cycle in the busiest sixty minutes, then buy the first-hour rating that covers it — DOE's method, and the reason a 40-gallon gas unit can out-deliver a 50-gallon electric. Buying gallons instead of FHR is how cold showers get purchased at full price.
The operating-cost math
The desk's read: the sticker is the down payment; UEF sets the monthly bill. Check the EnergyGuide label's estimated yearly cost, then run it against your own utility rate before comparing prices. A heat-pump unit near 4.0 UEF against a resistance tank near 0.93 is the widest efficiency spread in the aisle — worth the arithmetic, and worth confirming the install requirements before the savings are spent.
First buy: the anode habit
The desk's read: if you are replacing a failed tank, ask what killed it — tanks commonly fail by internal corrosion once the sacrificial anode is spent, which is the part's whole job. Start the new one differently: put an anode inspection on the calendar per the use-and-care manual, flush sediment on the same schedule, and know where the T&P valve discharges. It is the cheapest ownership habit in water heating.
Put your busiest hour on a list — showers, dishwasher, laundry — and a specialist sizes the first-hour rating before you buy. Paste the list, however you have it
The working collection
The tank bench
Gas, electric, and hybrid — sized by first-hour rating, not the gallon stamp.

Rheem
Performance 40 Gal. Short 6-Year 34,000 BTU Natural Gas Tank Water Heater
$599.00 each
Rheem
6 Gallon Electric Water Heater
$722.98 each
Rheem
RRTGHSR84I700193 IKONIC™ 157 MBH Indoor Condensing Natural Gas/Propane Gas Tankless Water Heater
$1,470.00 each
Rheem
RRTGHSR11I700191 IKONIC™ 199 MBH Indoor Condensing Natural Gas/Propane Gas Tankless Water Heater
$1,990.00 each

Illustrative production study, not a photograph of the maker's own facility.
Asked at the desk
Questions, answered plainly
What is a water heater's first-hour rating (FHR)?
First-hour rating is the U.S. Department of Energy's estimate of the maximum gallons of hot water a storage water heater can supply in an hour that begins with the tank fully heated — stored volume plus recovery rate combined. It appears on the yellow EnergyGuide label. DOE sizing guidance matches FHR to a household's peak-hour demand, which makes FHR, not tank gallons, the number that sizes a home.
What does UEF mean on a water heater?
Uniform Energy Factor is the Department of Energy's water heater efficiency metric, adopted in 2017 to replace the older Energy Factor. It measures how much of the energy a unit consumes becomes hot water over a standardized 24-hour test. Models are grouped into usage bins by first-hour rating, and UEF comparisons are valid only within the same bin. A higher UEF means lower operating cost for equivalent duty.
What is the difference between Rheem Performance and Professional water heaters?
They are tier families sorted by sales channel. Performance and Performance Platinum tanks sell through retail — Home Depot listings carry them — while Professional Classic, Professional Classic Plus, and Professional Prestige appear on Rheem's own catalog and through plumbing distributors. Specifications and warranties vary by individual model rather than by name alone, so compare first-hour rating, UEF, and warranty terms line by line.
What is the Rheem ProTerra?
ProTerra is Rheem's hybrid electric heat-pump water heater line, introduced in 2020. It heats water by moving heat from the surrounding air into the tank — a method NYSERDA credits with around three times the efficiency of standard electric resistance — with backup elements for high demand. Rheem rates ProTerra models up to 4.07 UEF and, per its own figures, up to 75 percent less energy use than a standard electric tank.
What does the anode rod in a water heater do?
The anode rod is a sacrificial magnesium or aluminum rod inside the tank that corrodes in place of the steel wall — its metal oxidizes more readily, so water consumes the rod instead of the tank. Rheem's parts guidance calls anode rods the most important line of defense for tank life and leak prevention, and notes that a depleted rod no longer protects. Periodic inspection and replacement extend tank life.
Who owns Rheem and where is it based?
Rheem Manufacturing Company was founded in 1925 in Emeryville, California, by the Rheem brothers, and has been a wholly owned subsidiary of Japan's Paloma group since 1988. Its headquarters moved to Atlanta, Georgia, in 2007. The company entered water heating in 1931, added HVAC in 1947, acquired the Ruud brand in 1960, and marked its centennial in 2025.
The hall closes. The water stays hot.
The Rheem lines above are live catalog — priced in the open, the same number for everyone. Water heating is a sizing buy: send your busiest hour, and a human specialist checks FHR, fuel, and fit before you order.
Citations: Rheem centennial history (rheem.com/100) · rheem.com product pages & spec sheets · parts.rheem.com component guides · Rheem use-and-care manuals · U.S. DOE Energy Saver & ENERGY STAR · FTC Energy Labeling Rule · Paloma Rheem Holdings · retailer and distributor listings. Era and anatomy imagery: styled visualizations, not archival photographs or Rheem drawings.
Rheem®, Ruud®, ProTerra®, EcoNet®, Rheemglas®, and related marks are trademarks of Rheem Manufacturing Company. © 2004–2026 Rheem Manufacturing Company. All rights reserved. Super Arbor is an independent retailer; brand marks remain the property of their respective owners.
