400 Amp 42-Space 42-Circuit Type CH Meter Socket and Main Breaker Load Center
42 spaces
$3,480.99 each
- 1 item
- $3,480.99
- Standard delivery
- $49.99 per order
- Sales tax
- Added at checkout
All orders are subject to approval.
You're not charged until your order is approved and ready to ship. Cancel free before then.
Standard delivery$49.99
Per order, added in your cart. We deliver to the 48 contiguous states.
Availability confirmed by the desk at approval, with your delivery date. Shipping policy · Returns
Complete the panel
Eaton · Electrical
Details & specifications.
From the maker · Eaton’s description
The Eaton 400 Amp 42-Space 42-Circuit Type CH Meter Socket and Main Breaker Load Center is NEMA 3R rated for outdoor use with a rainproof design. This combination unit is intended for use as both a main breaker load center and as a meter socket and it is also rated for use as service entrance equipment. The center's load conductors can exit the top, bottom, side or back for application and installation flexibility and has a socket-to-distribution section that is connected via an insulated cable for safety.
- For use as a combination main breaker load center and meter socket
- Rated for service entrance equipment
- NEMA 3R rated for outdoor use with a rainproof design
- Copper buss
- SKU
- 304547784
- UPC
- 782114105825
- Spaces
- 42
- Mounting
- Bolt On
- Location
- Indoor, Outdoor
- Brand
- Eaton
- Item Weight
- 114
- Number of Circuits
- 42
- Indoor/Outdoor
- Indoor, Outdoor
- Maximum Amperage (amps)
- 400
- Load Center Type
- Main Breaker
- Electrical Product Type
- Load Center
- Product Weight (lb.)
- 114 lb
- Phase Type
- 1 Phase
- Load Center Mounting Type
- Flush
- Voltage (volts)
- 240/120
- Load center width (in.)
- 32
- Load center height (in.)
- 46
- Load center depth (in.)
- 8
- Manufacturer Warranty
- Limited lifetime
- Certifications and Listings
- UL Listed
Specifications are provided by the manufacturer. Brand names are trademarks of their owners.
Guide
Before you buy a breaker
- 1
Match the panel
Find the brand and series on the label inside the panel door. Homeline and QO are both Square D, and they do not interchange.
- 2
Match the wire
The breaker protects the wire. For copper: 14 AWG on 15 A, 12 AWG on 20 A, 10 AWG on 30 A.
- 3
Protection
Standard, AFCI (arc fault), GFCI (ground fault) or dual function. Your local code says which circuits need which.
- 4
Tandem and quad
Two circuits in one space, only in the slots the panel label allows.