Skip to content
1 / 8

Siemens · Electrical

ES Series 200 Amp 30-Space 54-Circuit Main Breaker Outdoor 3-Phase Load Center

30 spaces

$644.00 each

Quantity
1 item
$644.00
Standard delivery
$49.99 per order
Sales tax
Added at checkout

All orders are subject to approval.

You're not charged until your order is approved and ready to ship. Cancel free before then.

Standard delivery$49.99

Per order, added in your cart. We deliver to the 48 contiguous states.

Availability confirmed by the desk at approval, with your delivery date. Shipping policy · Returns

Siemens · Electrical

Details & specifications.

From the maker · Siemens’s description

The new Siemens ES Series Load Center is the smart choice when value and quick installation are of highest priority. The ES Series load centers include labor saving features such as the patented Insta-wire and mounting trim tabs. These exclusive features make the ES Series load center the best load center for the value minded contractor.

  • 3 phase, 120/240 or 120/208-Volt, 200 Amp main breaker load center with 30-spaces/54-circuits
  • Aluminum bus
  • Ground bar field installed
  • Combination head screws on neutrals, ground, trim, upper pan, and bond screw provide installation flexibility
  • Dual side inboard neutral
  • Invertible for bottom feed application
  • All ES series load centers allow the main breaker to be converted to main lug, but not vice versa
  • Mounting tabs on the trim hold it in place on the load center, freeing up both hands to drive the trim screws
  • Pre-positioned bond screw eliminated bond straps/screw assemblies and reduce the risk of losing components in the field
  • Insta-wire neutral/ground system allows for faster installation because screws arrive backed out, ready for wire insertion, the visible neutral and grounds systems also aids in the insertion of conductors
  • Rigid, sturdy base pan provides ruggedness required for harsh applications
  • NEMA type 3: enclosure is intended for outdoor use primarily to provide a degree of protection against falling rain and sleet and must remain undamaged by the formation or ice on the enclosure; they are not intended to provide protection against conditions such as dust, internal condensation, or internal icing
SKU
205856746
Spaces
30
Mounting
Bolt On
Location
Outdoor
Circuits
54
Brand
Siemens
Item Weight
46
Voltage (volts)
120
Load Center Type
Main Breaker
Load Center Mounting Type
Surface
Electrical Product Type
Load Center
Phase Type
3 Phase
Indoor/Outdoor
Outdoor
Product Weight (lb.)
46
Maximum Amperage (amps)
200
Load center depth (in.)
5
Load center height (in.)
39.625
Load center width (in.)
15.5
Certifications and Listings
UL Listed
Manufacturer Warranty
10 Year

Specifications are provided by the manufacturer. Brand names are trademarks of their owners.

Guide

Before you buy a breaker

  1. 1

    Match the panel

    Find the brand and series on the label inside the panel door. Homeline and QO are both Square D, and they do not interchange.

  2. 2

    Match the wire

    The breaker protects the wire. For copper: 14 AWG on 15 A, 12 AWG on 20 A, 10 AWG on 30 A.

  3. 3

    Protection

    Standard, AFCI (arc fault), GFCI (ground fault) or dual function. Your local code says which circuits need which.

  4. 4

    Tandem and quad

    Two circuits in one space, only in the slots the panel label allows.