GAF MasterFlow 960 Series Aluminum Slant-Back Roof Louver, Black - image 1

GAF MasterFlow 960 Series Aluminum Slant-Back Roof Louver, Black

Regular price $23.94

Orders start at $399 — combine any items to reach the minimum. Learn more

/
Shipping calculated at checkout.

GAF MasterFlow 960 Series Aluminum Slant-Back Roof Louver, Black


This GAF MasterFlow 960 Series roof louver is a slant-back attic exhaust vent made of aluminum with a black finish. Each vent provides 60 sq. in. of net free vent area, fits a 10 in. opening, and is sold as a single piece. Pair it with soffit intake vents to maintain balanced attic ventilation.


Key Features:

  • High venting capacity: Provides 60 sq. in. of net free area per vent, about 20% more than typical 50 sq. in. NFA vents.
  • Slant-back design: The slant-back profile offers strong protection against weather infiltration, especially on steep-slope roofs.
  • Aluminum construction: Non-corrosive, non-combustible aluminum construction in a black finish.
  • Easy installation: Pre-drilled nail holes help make installation easy.
  • Code approved: Miami-Dade County Product Control Approved, Florida Building Code FL5027, Texas Department of Insurance RV-38, and CSA Certified.
  • Warranty eligible: Eligible accessory product in the Attic Ventilation category of GAF residential enhanced warranties.
  • Versatile use: Works on roofs with limited ridge line or when replacing existing roof louvers, on pitches 3:12 and greater.

Specifications Table:

Specification Details
Brand GAF
Manufacturer model 16SSB9A
Sell unit 1 roof louver
Product line MasterFlow 960 Series (SSB960 Metal Super Slant-Back)
Profile / style Slant-back roof louver
Color Black
Nominal size Fits 10 in. opening
Height 5 1/2 in. (140 mm)
Net free vent area 60 sq. in. (41,935 sq. mm)
Material Aluminum
Finish / texture Black
Allowable roof pitch 3:12 or greater
Weight 2.18 lb (gross)
Approvals Miami-Dade County Approved; Florida Building Code FL5027; Texas Department of Insurance Product Evaluation RV-38; CSA Certified; meets certain FORTIFIED Roof requirements

Fit and Compatibility:

Part of the GAF MasterFlow ventilation line; pair with GAF soffit or eave intake vents so exhaust never exceeds intake. Eligible accessory in the Attic Ventilation category of GAF residential enhanced warranties.


Frequently Asked Questions (FAQ):

Q: How many vents do I need for my attic?
A: GAF recommends a minimum of 1 sq. ft. of net free ventilation per 300 sq. ft. of attic floor space. For example, an attic of 1,001 to 1,500 sq. ft. calls for 6 of these 60 sq. in. louvers.


Q: What is included with my order?
A: One black aluminum slant-back roof louver. Intake ventilation must be provided separately at the soffits or eaves.


Q: What roof pitches does it fit?
A: It is rated for roof pitches of 3:12 and greater, with a 10 in. opening size and 5 1/2 in. height.


Q: Is it weather resistant?
A: The slant-back design offers strong protection against weather infiltration, and non-corrosive, non-combustible aluminum construction stands up to the elements.


Q: Does it qualify for GAF warranty benefits?
A: Yes, it is an eligible accessory product in the Attic Ventilation category of GAF residential enhanced warranties.


Q: Is there a fire-rated screen option?
A: Some SSB960 models are available with an optional internal weather/ember-resistant screen; check with the authority having jurisdiction before use, as GAF makes no express or implied warranty about fire performance against wildfire exposure.


Expert Verdict — Reviewed by the SuperArbor Pro Desk

Choose slant-back louvers on roofs with limited ridge line or when swapping out older box vents during a re-roof. Keep the ventilation balanced: exhaust at or near the ridge must never exceed intake at the soffit, so plan intake venting at the same time. At 60 sq. in. NFA each, these vents reduce the number of penetrations versus 50 sq. in. units. Follow the manufacturer's installation instructions and local building codes for placement and fastening.

Always consult local building codes for specific ventilation requirements and follow safe roof work practices; exhaust ventilation must never exceed intake ventilation.


Order the GAF MasterFlow 960 Series black aluminum slant-back roof louver for dependable attic exhaust ventilation.

*Third Party Trademarks

All third party trademarks, including logos and icons, referenced on our website and product pages remain the property of their respective owners. Unless specifically identified as such, Arbor's use of third party trademarks does not indicate any relationship, affiliation, sponsorship, or endorsement between Arbor Home and the owners of these trademarks. Any references by Arbor Home to third party trademarks are to identify the corresponding third party goods.

Subject to Approval & Availability
All orders are reviewed before fulfillment. You are not charged until your order is approved and ready to ship — and you may cancel at any time before that at no cost.

Why choose us

The Arbor Way

• Lowest Prices. Easy Online Shopping. Fast Delivery.

• No lines. No holds. No Hassles.

• America's Largest Inventory Network for All Home Improvement Supplies Nationwide.

• We deliver - town to town, door to door. 


Recently viewed