{"product_id":"portals-plus-deck-mate-3-pipe-flashing-for-metal-roofs-gray-1-4-in-to-4-in-openings","title":"Portals Plus Deck-Mate #3 Pipe Flashing for Metal Roofs - Gray, 1\/4 in. to 4 in. Openings","description":"\u003ch1\u003ePortals Plus Deck-Mate #3 Pipe Flashing for Metal Roofs - Gray, 1\/4 in. to 4 in. Openings\u003c\/h1\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003ePortals Plus Deck-Mate #3 is a compression-seal pipe flashing for metal roof and wall systems, sized for 1\/4 in. to 4 in. schedule 40 piping in gray. Its stepped profile creates a mechanical seal without caulk, and reinforcing ribs maintain shape while accepting a stainless steel clamp. Sold individually.\u003c\/strong\u003e\u003c\/p\u003e\u003chr\u003e\u003ch2\u003eKey Features:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompression Seal:\u003c\/strong\u003e A stepped profile creates a compression seal between schedule 40 piping and the flashing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReinforcing Ribs:\u003c\/strong\u003e Proper reinforcing ribs let the flashing maintain rigidity and its shape.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamp Ready:\u003c\/strong\u003e The stepped profile and ribs together properly accommodate the use of a stainless steel clamp.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Caulk Needed:\u003c\/strong\u003e Unlike caulk-sealed penetrations, the NRCA states caulk should never be used as the primary sealer of a penetration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetal Roof Ready:\u003c\/strong\u003e Designed specifically for metal roof and wall systems.\u003c\/li\u003e\n\u003c\/ul\u003e\u003chr\u003e\u003ch2\u003eSpecifications Table:\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePortals Plus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSell unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 each\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDeck-Mate pipe flashing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAvailable colors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGray\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAvailable sizes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e#3 opening, fits 1\/4\" - 4\" pipe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor \/ finish\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGray\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePipe range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4 in. to 4 in. schedule 40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStepped profile with reinforcing ribs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSealing method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompression seal with stainless steel clamp (clamp referenced, not confirmed included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntended use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMetal roof and wall penetration flashing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNRCA better roofing practices cited against caulk-only sealing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003chr\u003e\u003ch2\u003eCoverage \u0026amp; How Much You Need:\u003c\/h2\u003e\u003cp\u003eNot applicable; each unit flashes one pipe penetration up to 4 inches in diameter.\u003c\/p\u003e\u003ch2\u003eFit and Compatibility:\u003c\/h2\u003e\u003cp\u003eFits schedule 40 piping on metal roof and wall systems in the 1\/4 to 4 inch range. Use with a stainless steel clamp at the pipe per the design; clamps and other flashing sizes sold separately.\u003c\/p\u003e\u003chr\u003e\u003ch2\u003eFrequently Asked Questions (FAQ):\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eQ: What pipe sizes does the #3 opening fit?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The #3 opening accommodates 1\/4 inch to 4 inch schedule 40 piping.\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eQ: Does it use caulk to seal?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No; its stepped profile creates a compression seal, and the NRCA states caulk should never be a primary penetration sealer.\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eQ: Is a clamp included?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The flashing is designed to accommodate a stainless steel clamp; whether a clamp is included is not stated in the sources.\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eQ: Where can it be used?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e On metal roof and wall systems as a pipe penetration flashing.\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eQ: How is it sold?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Sold individually in gray.\u003c\/p\u003e\u003chr\u003e\u003ch2\u003eExpert Verdict — Reviewed by the SuperArbor Pro Desk\u003c\/h2\u003e\u003cp\u003eOn standing-seam and other metal systems, a compression-style pipe boot like the Deck-Mate beats caulk-only boots because the stepped profile seals mechanically as the pipe moves. Size the unit to the pipe diameter range and secure it with a stainless clamp per the design. Keep rib orientation per the installation instructions so rigidity is preserved on sloped panels.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eFollow roof-safety and fall-protection practices when working around penetrations on metal roofing.\u003c\/em\u003e\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eOrder the Portals Plus Deck-Mate #3 pipe flashing for a caulk-free compression seal on metal roof penetrations.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Portals Plus","offers":[{"title":"Default Title","offer_id":53522927419759,"sku":"PORPDM3144","price":16.43,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0830\/3499\/7051\/files\/ProductImage_PORDM1.jpg?v=1790233990","url":"https:\/\/superarbor.io\/products\/portals-plus-deck-mate-3-pipe-flashing-for-metal-roofs-gray-1-4-in-to-4-in-openings","provider":"Super Arbor","version":"1.0","type":"link"}