{"product_id":"ohagin-eagle-cap-monier-espana-attic-vent-galvanized-steel-26-gauge","title":"O'Hagin Eagle Cap Monier Espana Attic Vent – Galvanized Steel, 26 Gauge","description":"\n    \u003ch1\u003eEagle Cap Monier Espana Galvanized Attic Vent\u003c\/h1\u003e\n    \u003cp\u003e\u003cstrong\u003ePatented two-piece attic vent for tile roofs, featuring a subflashing primary vent and a profile-specific cover. Built from 26-gauge galvanized steel to deliver superior NFVA while preserving the look of Monier Espana tile profiles.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003chr\u003e\n    \u003ch2\u003eKey Features:\u003c\/h2\u003e\n    \u003cul\u003e\n        \u003cli\u003e\n\u003cstrong\u003eTile-Roof Specific Design:\u003c\/strong\u003e Two-piece system (subflashing + cover) tailored for Monier Espana profiles\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e 26-gauge galvanized steel resists corrosion and weathering\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Ventilation Performance:\u003c\/strong\u003e Engineered for superior Net Free Ventilation Area (NFVA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode-Compliant Safety:\u003c\/strong\u003e Class A fire rated and Miami-Dade approved; WUI compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClean Aesthetics:\u003c\/strong\u003e Low-profile cover maintains the appearance of surrounding roofing material\u003c\/li\u003e\n    \u003c\/ul\u003e\n    \u003cp\u003e\u003cstrong\u003ePlease check the Product Data Sheet \u003ca href=\"https:\/\/superarbor.io\/cdn\/shop\/files\/StandardOHagin_Tile_TriFold_FINAL_19-0311_252d4a78-188e-4995-86e1-9826349ecfeb.pdf?v=1763096784\" target=\"_blank\"\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003eHere\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n    \u003chr\u003e\n    \u003ch2\u003eSpecifications Table:\u003c\/h2\u003e\n    \u003ctable\u003e\n        \u003cthead\u003e\n            \u003ctr\u003e\n                \u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n                \u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n            \u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n            \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGalvanized Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGauge\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e26 Gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-piece (primary vent\/subflashing + profile-specific cover)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStyle\/Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTile Roofing; Monier Espana profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\/Approvals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eICC-ES Legacy Report 9650-A; Class A Fire Rated; Miami-Dade County Product Control Approved; Complies with Wildland Urban Interface Code Requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit of Measure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e504503000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOHAECMEG\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/tbody\u003e\n    \u003c\/table\u003e\n    \u003chr\u003e\n    \u003ch2\u003eFrequently Asked Questions (FAQ):\u003c\/h2\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: Is this vent compatible with all tile roofs?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e It is designed for Monier Espana tile profiles; select the profile-specific cover for proper fit.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: What materials are used?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e The vent is constructed from 26-gauge galvanized steel for strength and corrosion resistance.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: Does it meet building codes?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e Yes—ICC-ES Legacy Report 9650-A, Class A Fire Rated, Miami-Dade Product Control Approved, and compliant with Wildland Urban Interface requirements.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: How is it installed?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e Install the primary vent (subflashing) beneath the tile and attach the profile-specific cover; follow the manufacturer’s installation instructions.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: What is the purpose of NFVA?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e Net Free Ventilation Area indicates the unobstructed area for airflow, helping reduce heat and moisture in the attic.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003ch2\u003eSleek Ventilation that Honors Tile Craft\u003c\/h2\u003e\n    \u003cp\u003eThis vent seamlessly merges utility with elegance, slipping beneath tile to preserve a refined roofline. The profile-specific cover is a subtle detail that keeps the aesthetic cohesive while boosting airflow. Pair it with warm terracotta tiles to emphasize texture and create a sophisticated, timeless silhouette. It’s a discreet essential that elevates the performance and polish of any luxury tile roof.\u003c\/p\u003e\n    \n    \u003chr\u003e\n    \u003cp\u003e\u003cstrong\u003eUpgrade your tile roof with code-compliant, high-performance ventilation—choose the O'Hagin Eagle Cap Monier Espana vent today.\u003c\/strong\u003e\u003c\/p\u003e\n    \n    \n    ","brand":"O'Hagin","offers":[{"title":"Default Title","offer_id":52396214387055,"sku":"458802","price":72.96,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0830\/3499\/7051\/files\/458802_default_hero.jpg?v=1763096788","url":"https:\/\/superarbor.io\/products\/ohagin-eagle-cap-monier-espana-attic-vent-galvanized-steel-26-gauge","provider":"Super Arbor","version":"1.0","type":"link"}