{"product_id":"o-hagin-504603000-o-hagin-barcelona-900-galvanized-steel-standard-flange-tile-roof-vent","title":"O'Hagin Barcelona 900 Galvanized Steel Standard Flange Tile Roof Vent","description":"\u003ch1\u003eO'Hagin Barcelona 900 Galvanized Steel Standard Flange Tile Roof Vent\u003c\/h1\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eThis O'Hagin Barcelona 900 roof vent is a galvanized steel standard flange attic ventilation unit designed for Boral Barcelona 900 tile roofs. It installs flush with the tile profile for a low-profile, weather-protected exhaust vent. Sold as a single piece.\u003c\/strong\u003e\u003c\/p\u003e\u003chr\u003e\u003ch2\u003eKey Features:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTile-matched profile:\u003c\/strong\u003e Designed for Boral Barcelona 900 tile profiles for an integrated appearance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanized steel:\u003c\/strong\u003e Steel construction with galvanized finish for corrosion resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard flange:\u003c\/strong\u003e Standard flange design for installation within the tile field.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAttic exhaust vent:\u003c\/strong\u003e Provides attic exhaust ventilation through the tile roof plane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCode approvals:\u003c\/strong\u003e ICC-ES Legacy Report 9650-A, Class A Fire Rated, Miami-Dade County Product Control Approved, and complies with Wildland Urban Interface Code requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\u003chr\u003e\u003ch2\u003eSpecifications Table:\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eO'Hagin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e504603000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSell unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBarcelona 900 tile roof vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProfile \/ style\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBarcelona 900, standard flange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGalvanized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSteel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFinish\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGalvanized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplicable standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eICC-ES Legacy Report 9650-A; Class A Fire Rated; Miami-Dade County Product Control Approved; complies with Wildland Urban Interface Code requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntended use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAttic exhaust ventilation for Barcelona 900 tile roofs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003chr\u003e\u003ch2\u003eFit and Compatibility:\u003c\/h2\u003e\u003cp\u003eMade for Boral Barcelona 900 concrete tile roofs; pair with other O'Hagin vents sized to the same profile. Net free vent area and installation details should be confirmed from O'Hagin literature; additional vents sold separately.\u003c\/p\u003e\u003chr\u003e\u003ch2\u003eFrequently Asked Questions (FAQ):\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eQ: What is included?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e One galvanized steel O'Hagin Barcelona 900 standard flange roof vent.\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eQ: Which tile does it fit?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e It is designed for the Boral Barcelona 900 tile profile; match the vent to your installed tile.\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eQ: Is it fire rated?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, it is Class A Fire Rated and Miami-Dade County Product Control Approved.\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eQ: How is it installed?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e It is installed within the tile field on the roof plane per O'Hagin's instructions; follow local ventilation code requirements.\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eQ: How many do I need?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Determine attic ventilation requirements from net free area and local code, then order the required number of vents.\u003c\/p\u003e\u003chr\u003e\u003ch2\u003eExpert Verdict — Reviewed by the SuperArbor Pro Desk\u003c\/h2\u003e\u003cp\u003eMatch the vent profile exactly to the installed tile to preserve the roof's appearance and weather performance. Calculate required net free vent area for the attic, split intake and exhaust roughly 50\/50 where possible, and space exhaust vents near the ridge. Verify tile fastening and flashing details per O'Hagin's installation instructions and local code.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eRoof vent installation involves working at height on tile; use proper fall protection and follow the manufacturer's installation instructions and local building code.\u003c\/em\u003e\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eOrder the O'Hagin Barcelona 900 galvanized standard flange vent for code-approved attic ventilation in tile roofs.\u003c\/strong\u003e\u003c\/p\u003e","brand":"O'Hagin","offers":[{"title":"Default Title","offer_id":53529507955055,"sku":"504603000","price":59.22,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0830\/3499\/7051\/files\/448553_default_hero.jpg?v=1790350616","url":"https:\/\/superarbor.io\/products\/o-hagin-504603000-o-hagin-barcelona-900-galvanized-steel-standard-flange-tile-roof-vent","provider":"Super Arbor","version":"1.0","type":"link"}