{"product_id":"ips-jimco-ballard-jl-10-1-way-roof-vent-with-tite-top-insulator-9-1-2-in-x-11-in-mill-alum","title":"IPS Jimco Ballard JL-10 1-Way Roof Vent with Tite-Top \u0026 Insulator, 9-1\/2 in. x 11 in. Mill Aluminum","description":"\u003ch1\u003eIPS Jimco Ballard JL-10 1-Way Roof Vent with Tite-Top \u0026amp; Insulator, 9-1\/2 in. x 11 in. Mill Aluminum\u003c\/h1\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eThe IPS Jimco Ballard JL-10 is a one-way roof vent in 9-1\/2 in. x 11 in. mill-finish aluminum with Tite-Top and insulator, recommended for all types of roofing systems. Install one vent per 900 sq. ft. of roof area; sold individually.\u003c\/strong\u003e\u003c\/p\u003e\u003chr\u003e\u003ch2\u003eKey Features:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOne-Way Airflow:\u003c\/strong\u003e A layer of one-way fabric lets moisture and air escape but not enter the roofing system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy Gauge Aluminum:\u003c\/strong\u003e Constructed of .063 gauge aluminum for durability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpun One-Piece Body:\u003c\/strong\u003e One-piece spun aluminum construction eliminates split seams and blown-off caps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFully Insulated:\u003c\/strong\u003e Fully insulated to eliminate condensation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo Moving Parts:\u003c\/strong\u003e No moving parts to wear out or clog due to insects or debris.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTite-Top Included:\u003c\/strong\u003e Comes with Tite-Top and insulator in a mill finish.\u003c\/li\u003e\n\u003c\/ul\u003e\u003chr\u003e\u003ch2\u003eSpecifications Table:\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSell unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJimco Ballard JL-10 1-Way Vent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAvailable colors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMill\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAvailable sizes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9-1\/2 in. x 11 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.063 gauge aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9-1\/2 in. x 11 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFinish \/ texture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMill aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVent type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOne-way vent system with Tite-Top and insulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoverage per unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 vent per 900 sq. ft. of roof area\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntended use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAll types of roofing systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssembly\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOne-piece spun aluminum construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003chr\u003e\u003ch2\u003eCoverage \u0026amp; How Much You Need:\u003c\/h2\u003e\u003cp\u003eInstall one JL-10 vent per 900 sq. ft. of roof area. Divide total roof area by 900 to determine the number of vents required.\u003c\/p\u003e\u003ch2\u003eFit and Compatibility:\u003c\/h2\u003e\u003cp\u003eRecommended for all types of roofing systems. Install per the roofing manufacturer's guidelines for ventilation and flash the vent base into the surrounding roof system.\u003c\/p\u003e\u003chr\u003e\u003ch2\u003eFrequently Asked Questions (FAQ):\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eQ: How many vents do I need?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Install one vent per 900 sq. ft. of roof area.\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eQ: What is included with the vent?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The JL-10 includes the Tite-Top and insulator in one mill-finish aluminum unit.\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eQ: How does the one-way system work?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e A one-way fabric layer allows moisture and air to escape while preventing entry into the roofing system.\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eQ: Can the cap blow off or clog?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The one-piece spun aluminum body eliminates split seams and blown-off caps, and there are no moving parts to clog with insects or debris.\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eQ: Will it condensate?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e It is fully insulated to eliminate condensation.\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eQ: What is it made of?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Heavy .063 gauge aluminum.\u003c\/p\u003e\u003chr\u003e\u003ch2\u003eExpert Verdict — Reviewed by the SuperArbor Pro Desk\u003c\/h2\u003e\u003cp\u003eThe JL-10's passive one-way fabric design suits roof assemblies where you want moisture and air to exhaust without mechanical parts or insect screening to maintain. Because spacing is fixed at one vent per 900 sq. ft., size the layout before ordering and mark vent locations clear of drains and equipment. Its spun aluminum body holds up well where stamped, seamed vents tend to fail.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eUse fall protection when installing rooftop vents, and cut roof openings only after verifying framing and utilities below.\u003c\/em\u003e\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eOrder the IPS Jimco Ballard JL-10 1-Way Vent for clog-free, condensation-controlled roof ventilation.\u003c\/strong\u003e\u003c\/p\u003e","brand":"IPS","offers":[{"title":"Default Title","offer_id":53525816181103,"sku":"IPS1BV","price":60.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0830\/3499\/7051\/files\/23800_default_hero.jpg?v=1790294010","url":"https:\/\/superarbor.io\/products\/ips-jimco-ballard-jl-10-1-way-roof-vent-with-tite-top-insulator-9-1-2-in-x-11-in-mill-alum","provider":"Super Arbor","version":"1.0","type":"link"}