{"product_id":"gaf-spf-flashing-foam-two-component-closed-cell-low-pressure-polyurethane-spray-foam-kit-r","title":"GAF SPF Flashing Foam, Two-Component Closed-Cell Low-Pressure Polyurethane Spray Foam Kit, R-6.6 per Inch","description":"\u003ch1\u003eGAF SPF Flashing Foam, Two-Component Closed-Cell Low-Pressure Polyurethane Spray Foam Kit, R-6.6 per Inch\u003c\/h1\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eGAF SPF Flashing Foam is a two-component, closed-cell, low-pressure, solvent-free polyurethane spray foam designed to fill and insulate penetrations and voids. It provides an unaged R-value of 6.6 per inch and 13.2 at 2 in. thick, and forms a continuous air barrier. The boxed kit suits cold storage and tilt-up wall applications from flat roof to parapet wall.\u003c\/strong\u003e\u003c\/p\u003e\u003chr\u003e\u003ch2\u003eKey Features:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClosed-Cell Foam:\u003c\/strong\u003e Two-component, closed-cell, low-pressure, solvent-free polyurethane foam spray.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFill \u0026amp; Insulate:\u003c\/strong\u003e Expands in penetrations, gaps and cracks to insulate and prevent air leakage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTested to ASTM E84:\u003c\/strong\u003e Tested to ASTM E84 with an FSI of 5 and SDI of 450 at 2 in. thickness.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrong R-Value:\u003c\/strong\u003e Provides R-6.6 at 1 in. thick and R-13.2 at 2 in. thick (unaged).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Indicator:\u003c\/strong\u003e Patented dispensing unit changes color to show chemical temperature is above the required 70°F tank install temperature.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous Air Barrier:\u003c\/strong\u003e Excellent adhesion creates a continuous air barrier that completes the building envelope.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-GWP Formula:\u003c\/strong\u003e Contains low-GWP propellants and no HFC.\u003c\/li\u003e\n\u003c\/ul\u003e\u003chr\u003e\u003ch2\u003eSpecifications Table:\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGAF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSell unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 box (HAZMAT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGAF SPF Flashing Foam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-component closed-cell polyurethane foam, solvent-free\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eR-value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.6 at 1 in. thick, 13.2 at 2 in. thick (unaged)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFire test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eASTM E84, FSI of 5 and SDI of 450 at 2 in. thickness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePropellants\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow-GWP, no HFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstall temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTank chemical temperature must be above 70°F (color-indicating dispensing unit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAvailable sizes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHAZMAT box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntended use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFilling and insulating penetrations and cavity gaps; cold storage and tilt-up wall applications, flat roof to parapet wall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssembly\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo-component low-pressure spray with patented dispensing unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003chr\u003e\u003ch2\u003eCoverage \u0026amp; How Much You Need:\u003c\/h2\u003e\u003cp\u003eYield per kit is not stated in the sources; size the job by the volume of penetrations, gaps and cavity voids to be filled at up to 2 in. nominal thickness.\u003c\/p\u003e\u003ch2\u003eFit and Compatibility:\u003c\/h2\u003e\u003cp\u003eIntended for commercial roofing applications such as cold storage and tilt-up wall building projects, filling penetrations and cavity gaps from flat roof surfaces to vertical parapet walls. Specific membrane compatibility should be confirmed with the roofing system requirements; not stated in the sources.\u003c\/p\u003e\u003chr\u003e\u003ch2\u003eFrequently Asked Questions (FAQ):\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eQ: What is included?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e A boxed two-component kit with a patented dispensing unit; the exact component count and yield are not stated in the sources.\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eQ: What R-value does it provide?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e R-6.6 at 1 in. thick and R-13.2 at 2 in. thick, unaged.\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eQ: Is it fire tested?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e It has been tested to ASTM E84, with an FSI of 5 and SDI of 450 at 2 in. thickness.\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eQ: What temperature is needed to install?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The tank chemical temperature must be above 70°F; the patented dispensing unit changes color to indicate this.\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eQ: Where is it used?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e It fills and insulates penetrations and voids, ideal for cold storage and tilt-up wall applications from flat roof to parapet wall.\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eQ: Does it stop air leaks?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, its expanding foam and adhesion create a continuous air barrier that completes the building envelope.\u003c\/p\u003e\u003chr\u003e\u003ch2\u003eExpert Verdict — Reviewed by the SuperArbor Pro Desk\u003c\/h2\u003e\u003cp\u003eLow-pressure two-component foam kits are well suited to flashing penetrations and cavity voids where large rigs are impractical. Check the dispensing unit's temperature indicator before spraying, since cold chemicals impair foam quality and yield. Spray in thin lifts at detail scale so the closed-cell foam cures evenly and does not over-expand beyond the void.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eTwo-component spray foams require appropriate PPE (gloves, eye protection, respirator) and ventilation per the product safety data sheet; the kit is classified HAZMAT for shipping.\u003c\/em\u003e\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eOrder the GAF SPF Flashing Foam kit to fill, insulate and air-seal roof penetrations with closed-cell polyurethane.\u003c\/strong\u003e\u003c\/p\u003e","brand":"GAF","offers":[{"title":"Default Title","offer_id":53522869879151,"sku":"GAF418007","price":730.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0830\/3499\/7051\/files\/GAF418007_0.jpg?v=1790231546","url":"https:\/\/superarbor.io\/products\/gaf-spf-flashing-foam-two-component-closed-cell-low-pressure-polyurethane-spray-foam-kit-r","provider":"Super Arbor","version":"1.0","type":"link"}