{"product_id":"flashco-flashjack-tpo-closed-conical-pipe-boot-60-mil-reinforced-membrane-multiple-sizes","title":"FlashCo FlashJack TPO Closed Conical Pipe Boot, 60 mil Reinforced Membrane, Multiple Sizes","description":"\u003ch1\u003eFlashCo FlashJack TPO Closed Conical Pipe Boot, 60 mil Reinforced Membrane, Multiple Sizes\u003c\/h1\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eThe FlashCo FlashJack TPO Closed Conical Boot is a Factory Certified prefabricated pipe flashing made from 60 mil reinforced TPO membrane for TPO low-slope roofs. It cuts to size on the roof to fit snugly over cylindrical penetrations while maintaining a riser height of at least 6 in. Six listings cover sizes from 0.5 in. to 9 in. pipe diameter in Gray and Slate Gray.\u003c\/strong\u003e\u003c\/p\u003e\u003chr\u003e\u003ch2\u003eKey Features:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrefabricated, Factory Certified:\u003c\/strong\u003e FlashJack flashings are Factory Certified prefabricated pipe flashings for consistent quality.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e60 mil reinforced TPO:\u003c\/strong\u003e The boot is made from 60 mil reinforced TPO membrane; the listing also cites a 70 mil thickness figure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSaves up to 60% labor:\u003c\/strong\u003e Prefabrication saves up to 60% of the labor of field fabrication.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRib design:\u003c\/strong\u003e The rib design makes cutting easy and keeps the clamp securely in place.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConsistent appearance:\u003c\/strong\u003e FlashJack makes flashing pipes cleaner and more consistent than field-fabricated boots.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRange fits many pipes:\u003c\/strong\u003e Each conical flashing fits a range of penetration diameters while maintaining a riser height of 6 in. or greater.\u003c\/li\u003e\n\u003c\/ul\u003e\u003chr\u003e\u003ch2\u003eSpecifications Table:\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlashCo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSell unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlashJack TPO Closed Conical Flashings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 mil reinforced TPO membrane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThickness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mil (as listed in feature text)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAvailable colors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGray, Slate Gray\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAvailable sizes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 in. to 2 in., 3 in. to 5 in., 5 in. to 7 in., 7 in. to 9 in. penetration ranges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRiser height at least 6 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntended use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlashing cylindrical pipe penetrations on TPO low-slope roofs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRib design for easy cutting and secure clamp location\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003chr\u003e\u003ch2\u003eFit and Compatibility:\u003c\/h2\u003e\u003cp\u003eMade for TPO low-slope roof systems; listings are offered in Versico and GAF membrane-color match listings. Choose the size range that brackets your pipe diameter and the membrane color that matches the roof field.\u003c\/p\u003e\u003chr\u003e\u003ch2\u003eFrequently Asked Questions (FAQ):\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eQ: What sizes are available?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Size ranges are 0.5 in. to 2 in., 3 in. to 5 in., 5 in. to 7 in. and 7 in. to 9 in.; pick the range that fits your pipe diameter.\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eQ: What colors are offered?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Gray and Slate Gray, with listings matched to Versico and GAF membrane systems.\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eQ: How does it install?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Slip the closed conical boot over the pipe, cut to size using the rib design guide, clamp in place and weld the base flashing into the TPO field per standard details.\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eQ: How thick is the membrane?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The boot is made from 60 mil reinforced TPO membrane; the feature list also cites a 70 mil thickness.\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eQ: How tall is the riser?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Each conical pipe flashing maintains a riser height of at least 6 in. or greater.\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eQ: Why not field-fabricate a boot?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e FlashCo states the prefabricated boot saves up to 60% of labor and gives a cleaner, more consistent appearance than field fabrication.\u003c\/p\u003e\u003chr\u003e\u003ch2\u003eExpert Verdict — Reviewed by the SuperArbor Pro Desk\u003c\/h2\u003e\u003cp\u003ePick the smallest size range that comfortably brackets the pipe so the cone clamps tight without over-stretching. Keep at least the 6 in. riser above the finished roof surface for ponding and splash exposure. Weld the base with the same brand's TPO details and primer where required, and stock a couple of size ranges since pipe bundles rarely match drawings exactly.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eTPO welding requires proper equipment and PPE; keep heat tools away from flammables and follow the membrane manufacturer's hot-air welding safety practices.\u003c\/em\u003e\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eOrder the FlashCo FlashJack TPO Closed Conical Boot in your size range for fast, consistent pipe flashing on TPO roofs.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Flashco","offers":[{"title":"Gray \/ 3\" to 5\" Versico \/ PC","offer_id":53522982797679,"sku":"FLAVSTPCN02G","price":37.5,"currency_code":"USD","in_stock":true},{"title":"Gray \/ 5\" to 7\" Versico \/ PC","offer_id":53522982830447,"sku":"FLAVSTPCN03G","price":58.0,"currency_code":"USD","in_stock":true},{"title":"Gray \/ 7\" to 9\" Versico \/ PC","offer_id":53522982863215,"sku":"FLAVSTPCN04G","price":52.0,"currency_code":"USD","in_stock":true},{"title":"Slate Gray \/ 3\" to 5\" GAF \/ PC","offer_id":53522982895983,"sku":"FLASTPCN02SG","price":46.5,"currency_code":"USD","in_stock":true},{"title":"Gray \/ 3\" to 5\" GAF \/ EA","offer_id":53522982928751,"sku":"FLASTPCN02G3","price":37.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0830\/3499\/7051\/files\/ProductImage_Flashco_FLAVSTPCN2A.jpg?v=1790235788","url":"https:\/\/superarbor.io\/products\/flashco-flashjack-tpo-closed-conical-pipe-boot-60-mil-reinforced-membrane-multiple-sizes","provider":"Super Arbor","version":"1.0","type":"link"}