{"product_id":"certainteed-flintlastic-gta-fr-coolstar-app-modified-bitumen-cap-sheet-roll-1-sq-100-sq-ft-white","title":"CertainTeed Flintlastic GTA-FR CoolStar APP Modified Bitumen Cap Sheet Roll (1 SQ \/ 100 sq ft, White)","description":"\n    \u003ch1\u003eCoolStar APP Modified Bitumen Cap Sheet Roll\u003c\/h1\u003e\n    \u003cp\u003e\u003cstrong\u003eCertainTeed Flintlastic GTA-FR CoolStar is a fire-resistant, highly solar-reflective, granulated APP-modified cap sheet designed for low-slope residential and commercial roofing. Built with a polyester reinforcement and CoolStar reflective granules, it’s engineered for torch application in APP modified bitumen roof system assemblies.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003chr\u003e\n    \u003ch2\u003eKey Features:\u003c\/h2\u003e\n    \u003cul\u003e\n        \u003cli\u003e\n\u003cstrong\u003eCool Roof Reflectivity:\u003c\/strong\u003e CoolStar reflective granules help meet ENERGY STAR requirements and reduce roof surface heat gain.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire-Resistant Performance:\u003c\/strong\u003e Fire-retardant additives support use in fire-rated roof assemblies (Class A, B, and C listings referenced).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTorch-Applied Installation:\u003c\/strong\u003e Designed for torch application only in APP modified bitumen systems (new construction or reroofing).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Reinforced Membrane:\u003c\/strong\u003e Polyester-reinforced, mineral-surfaced cap sheet for durable low-slope field and flashing applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Use Cases:\u003c\/strong\u003e Suitable for low-slope roofs and roof system flashings including wall treatments, base flashings, and field flashings.\u003c\/li\u003e\n    \u003c\/ul\u003e\n    \u003cp\u003e\u003cstrong\u003ePlease check the Product Data Sheet \u003ca href=\"https:\/\/superarbor.io\/cdn\/shop\/files\/tech-data-Flintlastic-GTA-FR-CoolStar-01-11-4094-NA-EN-2407.pdf?v=1768439805\" target=\"_blank\"\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003eHere\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n    \u003chr\u003e\n    \u003ch2\u003eSpecifications Table:\u003c\/h2\u003e\n    \u003ctable\u003e\n        \u003cthead\u003e\n            \u003ctr\u003e\n                \u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n                \u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n            \u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n            \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCertainTeed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlintlastic GTA-FR CoolStar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRoofing Materials\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSub-category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAPP Modified Bitumen Membranes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit of measure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRL (Roll)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTorch-applied (intended for torch application only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial \/ construction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyester mineral surfaced APP cap sheet with fire retardant additives and reflective CoolStar granules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntended use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRoofing membrane cap sheet in APP modified bitumen roof system assemblies; suitable for low-slope residential and commercial use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitable installations\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNew construction and reroofing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlashing use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMay be used for roof system flashings including wall treatments, base flashings and field flashings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWhite (CoolStar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoll coverage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 sq. ft. per roll (1 SQ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e39-3\/8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 ft 10 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThickness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e156 mil (3.96 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eItem weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplicable standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eASTM D6222, Grade G, Type I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eListings\/approvals (referenced)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL Class A, B and C; ICC-ES ESR-1388; Factory Mutual Approved; Miami-Dade County Approved; Florida Building Code Approved (FL2533 and FL16709); Texas Department of Insurance (RC-47); Energy Star; CRRC\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/tbody\u003e\n    \u003c\/table\u003e\n    \u003chr\u003e\n    \u003ch2\u003eFrequently Asked Questions (FAQ):\u003c\/h2\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: Is this membrane torch-applied or self-adhered?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e It is intended for torch application only.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: What area does one roll cover?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e One roll covers 100 sq. ft. (1 square).\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: Can it be used for flashing details?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e Yes—it's suitable for roof system flashings including wall treatments, base flashings, and field flashings.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: What color is the CoolStar version?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e This CoolStar variant is listed as White \/ CoolStar.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: What standards\/approvals does it meet?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e It is listed to ASTM D6222 (Grade G, Type I) and references approvals such as UL Class A\/B\/C, ICC-ES ESR-1388, Factory Mutual, Miami-Dade, and Florida Building Code (varies by assembly and jurisdiction).\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003ch2\u003eA crisp, cool-roof finish that elevates the fifth façade\u003c\/h2\u003e\n    \u003cp\u003eThink of the roof as the building’s quiet couture—the surface that absorbs sun, sky, and scale. Flintlastic GTA-FR CoolStar brings a luminous, mineral-granulated finish with solar-reflective performance, turning a utilitarian plane into a refined, high-functioning layer. Use it to keep low-slope roofs looking clean and bright while supporting fire-resistant design requirements. It’s the kind of practical luxury that makes a space feel considered from every angle—even the one above.\u003c\/p\u003e\n    \n    \u003chr\u003e\n    \u003cp\u003e\u003cstrong\u003eChoose Flintlastic GTA-FR CoolStar for a fire-resistant, solar-reflective cap sheet engineered for durable low-slope roofing performance.\u003c\/strong\u003e\u003c\/p\u003e\n    \n    \n    ","brand":"CertainTeed","offers":[{"title":"Default Title","offer_id":52580569547119,"sku":"06CTFPGTCS","price":210.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0830\/3499\/7051\/files\/flintlasticGTAFR-CoolStar-09-dml.jpg?v=1768439810","url":"https:\/\/superarbor.io\/products\/certainteed-flintlastic-gta-fr-coolstar-app-modified-bitumen-cap-sheet-roll-1-sq-100-sq-ft-white","provider":"Super Arbor","version":"1.0","type":"link"}