{"product_id":"basf-skytite®-c3-2-5-series-closed-cell-spray-foam-roofing-insulation-resin-part-b-polyol-500-lb-amber-sku-50659844","title":"BASF SKYTITE® C3-2.5 Series Closed-Cell Spray Foam Roofing Insulation Resin (500 lb Drum)","description":"\n    \u003ch1\u003eClosed-cell spray foam roofing insulation resin\u003c\/h1\u003e\n    \u003cp\u003e\u003cstrong\u003eBASF SKYTITE® C3 2.5 is a closed-cell roofing resin designed to be combined with Elastospray 8000A isocyanate to create a high-density spray polyurethane foam roof insulation system. Formulated with “F” reactivity for colder\/winter conditions, it helps deliver durable, insulating performance on roofing applications.\u003c\/strong\u003e\u003c\/p\u003e\n    \u003chr\u003e\n    \u003ch2\u003eKey Features:\u003c\/h2\u003e\n    \u003cul\u003e\n        \u003cli\u003e\n\u003cstrong\u003eHigh-Density Closed-Cell Foam System:\u003c\/strong\u003e Produces nominal 2.5 pcf spray polyurethane foam when combined with Elastospray 8000A isocyanate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold-Weather Reactivity:\u003c\/strong\u003e “F” reactivity is designed for colder climatic conditions through winter months.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJobsite-Ready Mixing:\u003c\/strong\u003e 1:1 mixing ratio for consistent proportioning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrum Quantity for Large Projects:\u003c\/strong\u003e 500 lb net content supports high-volume roofing insulation work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication-Focused Handling Specs:\u003c\/strong\u003e Recommended temperature range 50–75°F and storage temperature 16–27°C.\u003c\/li\u003e\n    \u003c\/ul\u003e\n    \u003cp\u003e\u003cstrong\u003ePlease check the Product Data Sheet \u003ca href=\"https:\/\/superarbor.io\/cdn\/shop\/files\/BASF_50659844_Specification_Sheet_4fa80418-55a4-4db2-aab0-3b8e2a86b8c8.pdf?v=1766980690\" target=\"_blank\"\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003eHere\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n    \u003chr\u003e\n    \u003ch2\u003eSpecifications Table:\u003c\/h2\u003e\n    \u003ctable\u003e\n        \u003cthead\u003e\n            \u003ctr\u003e\n                \u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n                \u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n            \u003c\/tr\u003e\n        \u003c\/thead\u003e\n        \u003ctbody\u003e\n            \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSKYTITE® C3-2.5 Series Closed Cell Spray Foam Roofing Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC3-2.5 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpray Foam Insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFoam type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed-cell spray polyurethane foam (system resin component)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem\/component\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRoofing resin; to be combined with Elastospray 8000A isocyanate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal density\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 pcf\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAmber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet content\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMixing ratio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1:1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShelf life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eViscosity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e320 mPa·s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDensity (listed range)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.25 to 2.45 lb\/g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 to 75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 to 27°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReactivity\/conditions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFast\/Winter Conditions (“F” reactivity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePart B Polyol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eComposition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTriethyl Phosphate; Cyclohexyldimethylamine; Diethylene Glycol; Tris(2-Chloro-1-Methylethyl)Phosphate; 1-Propene, 1-Chloro-3,3,3-Trifluoro; 4-Nonylphenol, Branched, Ethoxylated; Bismuth; 2,2',2'',2'''-(1,2-Ethanediyldinitrilo)Tetrakis[Ethanol] Neodecanoate Polypropylene Glycol Complexes; Ethylene Oxide, Polymer with 2,2'-Iminodiethanol and Propylene Oxide; Oxirane, 2-Methyl, Polymer with Oxirane; Ether with 2,6-Bis[[Bis(2-Hydroxyethyl)Amino]Methyl]-4-Branched Nonylphenol; Aromatic Amino Polyol; 2,2'-Dimorpholinyldiethylether; Polyetherpolyol, Halogenated; Ethylene Glycol; 1,2-Benzenedicarboxylic Acid, 3,4,5,6-Tetrabromo, Mixed Esters with Diethylene Glycol and Propylene Glycol; Hexanoic Acid, 2-Ethyl, Bismuth(3+) Salt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarning\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCalifornia Proposition 65 warning (see www.P65Warnings.ca.gov)\u003c\/td\u003e\n\u003c\/tr\u003e\n        \u003c\/tbody\u003e\n    \u003c\/table\u003e\n    \u003chr\u003e\n    \u003ch2\u003eFrequently Asked Questions (FAQ):\u003c\/h2\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: What is this product used for?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e It is a closed-cell spray foam roofing resin (Part B polyol) used to produce insulating roof foam when combined with Elastospray 8000A isocyanate.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: Does this product require a second component?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e Yes. It must be combined with Elastospray 8000A isocyanate to produce the spray polyurethane foam system.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: What is the mixing ratio?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e The listed mixing ratio is 1:1.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: What conditions is it formulated for?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e It is noted as “F” reactivity intended for colder climatic conditions through winter months.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003cp\u003e\u003cstrong\u003eQ: What are the storage and use temperature ranges?\u003c\/strong\u003e\u003cbr\u003e\n    \u003cstrong\u003eA:\u003c\/strong\u003e Storage temperature is listed as 16–27°C; temperature rating is listed as 50–75°F.\u003c\/p\u003e\n    \u003chr\u003e\n    \n    \u003ch2\u003eArchitectural comfort, elevated—right from the roofline\u003c\/h2\u003e\n    \u003cp\u003eThere’s something quietly luxurious about a home that feels perfectly tempered—cool, calm, and protected—starting at the roof. SKYTITE® C3 2.5 brings that confidence with a high-density, closed-cell spray foam system engineered for demanding conditions, even when winter weather sets the tone. Use it to create a more resilient building envelope where performance becomes an invisible design detail. It’s the kind of foundational upgrade that makes everyday living feel unmistakably refined.\u003c\/p\u003e\n    \n    \u003chr\u003e\n    \u003cp\u003e\u003cstrong\u003eUpgrade your roof’s insulation performance—spec SKYTITE® C3-2.5 for a high-density closed-cell spray foam system built for colder-condition applications.\u003c\/strong\u003e\u003c\/p\u003e\n    \n    \n    ","brand":"BASF","offers":[{"title":"Default Title","offer_id":52533914468719,"sku":"50659846","price":51.43,"currency_code":"USD","in_stock":true}],"url":"https:\/\/superarbor.io\/products\/basf-skytite%c2%ae-c3-2-5-series-closed-cell-spray-foam-roofing-insulation-resin-part-b-polyol-500-lb-amber-sku-50659844","provider":"Super Arbor","version":"1.0","type":"link"}