{"product_id":"acm-5-1-4-in-right-gutter-end-cap-aluminum","title":"ACM 5-1\/4 In. Right Gutter End Cap, Aluminum","description":"\u003ch1\u003eACM 5-1\/4 In. Right Gutter End Cap, Aluminum\u003c\/h1\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eThe ACM Right End Cap is a 5-1\/4 in. gutter end cap for closing the right end of a gutter run. Each sell unit is one piece. It pairs with matching 5-1\/4 in. gutter coil and the left end cap to complete gutter runs.\u003c\/strong\u003e\u003c\/p\u003e\u003chr\u003e\u003ch2\u003eKey Features:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRight-hand cap:\u003c\/strong\u003e Formed as a right end cap for closing the right end of a gutter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5-1\/4 in. size:\u003c\/strong\u003e Sized for 5-1\/4 in. gutter profiles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle piece:\u003c\/strong\u003e Sold as one piece per order unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeals run ends:\u003c\/strong\u003e Closes the open gutter end to keep water directed to the outlet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem match:\u003c\/strong\u003e Pairs with the matching left end cap and gutter coil.\u003c\/li\u003e\n\u003c\/ul\u003e\u003chr\u003e\u003ch2\u003eSpecifications Table:\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eACM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSell unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePG 5-1\/4\" End Cap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5-1\/4 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrientation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntended use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosing the right end of a 5-1\/4 in. gutter run\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003chr\u003e\u003ch2\u003eFit and Compatibility:\u003c\/h2\u003e\u003cp\u003eFits 5-1\/4 in. gutter formed from matching ACM gutter coil; use with the matching ACM left end cap on the opposite end. End caps must be sealed with gutter sealant (sold separately) for a watertight joint.\u003c\/p\u003e\u003chr\u003e\u003ch2\u003eFrequently Asked Questions (FAQ):\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eQ: What is included?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e One right end cap sized for 5-1\/4 in. gutter.\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eQ: Which end does this cap fit?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e This is the right end cap; order the matching left end cap for the opposite end of the run.\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eQ: Do I need sealant?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, apply gutter sealant at the joint per standard practice for a watertight installation.\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eQ: What gutter size does it match?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e It is made for 5-1\/4 in. gutter, matching the ACM gutter coil line.\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eQ: How is it attached?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e It is crimped or snapped onto the gutter end and sealed, following standard gutter installation practice.\u003c\/p\u003e\u003chr\u003e\u003ch2\u003eExpert Verdict — Reviewed by the SuperArbor Pro Desk\u003c\/h2\u003e\u003cp\u003eOrder both right and left end caps for each straight run and check orientation before crimping. Seal the lap with gutter sealant and let it cure fully before testing water flow. Match the cap color and material to the gutter coil for a clean, uniform finish.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eWear gloves and eye protection when crimping end caps; metal edges can be sharp, and use stable ladder setup when working at height.\u003c\/em\u003e\u003c\/p\u003e\u003chr\u003e\u003cp\u003e\u003cstrong\u003eOrder the ACM 5-1\/4 in. right gutter end cap to finish your gutter run.\u003c\/strong\u003e\u003c\/p\u003e","brand":"ACM","offers":[{"title":"Default Title","offer_id":67587066986863,"sku":"PEC52R","price":2.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0830\/3499\/7051\/files\/Gutter-Coil-Accessories-SKU_2275095-primary.png?v=1790448600","url":"https:\/\/superarbor.io\/products\/acm-5-1-4-in-right-gutter-end-cap-aluminum","provider":"Super Arbor","version":"1.0","type":"link"}